1,638 research outputs found
Advances in the Development of Micropattern Gaseous Detectors with Resistive Electrodes
We describe the most recent efforts made by various groups in implementing
resistive electrodes in micropattern gaseous detectors with the aim to combine
in the same design the best features of RPCs (for the example, their robustness
and spark protection property) with the high granularity and thus the good
position resolution offered by microelectronic technology. In the stream of
this activity, we have recently developed two novel detectors with resistive
electrodes: one was based on resistive micromeshes and the second one is a MSGC
with resistive electrodes. We have demonstrated that the resistive meshes are a
convenient construction element for various designs of spark protective
detectors: RPCs type, GEM type and MICROMEGAS type. These new detectors enable
to considerably enhance the RPC and micropattern detectors applications since
they feature not only a high position resolution but also a relatively good
energy resolution (25-30 persent FWHM at 6 keV) and, if necessary, they can
operate in cascaded mode allowing the achievement of a high overall gas gain.
The main conclusion from these studies is that the implementation of resistive
electrodes in micropattern detectors makes them fully spark protected; on this
basis we consider this direction very promising
RNF11 (ring finger protein 11)
Review on RNF11, with data on DNA/RNA, on the protein encoded and where the gene is implicated
MINT, the molecular interaction database: 2012 update
The Molecular INTeraction Database (MINT, http://mint.bio.uniroma2.it/mint/) is a public repository for protein-protein interactions (PPI) reported in peer-reviewed journals. The database grows steadily over the years and at September 2011 contains approximately 235,000 binary interactions captured from over 4750 publications. The web interface allows the users to search, visualize and download interactions data. MINT is one of the members of the International Molecular Exchange consortium (IMEx) and adopts the Molecular Interaction Ontology of the Proteomics Standard Initiative (PSI-MI) standards for curation and data exchange. MINT data are freely accessible and downloadable at http://mint.bio.uniroma2.it/mint/download.do. We report here the growth of the database, the major changes in curation policy and a new algorithm to assign a confidence to each interaction
Evaluation of the imaging performance of the TECNOMUSE muon tomograph and its feasibility in a real scenario
Muon tomography is a very promising imaging technique for the control of cargo
containers. It takes advantage of cosmic muons and their interaction mechanisms to reconstruct
images of the volume traversed by these particles. In the present work, the imaging
performance of a novelmuon tomography scanner based on resistive plate chambers detectors
is investigated. By means of several Monte Carlo simulations, some imaging parameters are
evaluated. The results in terms of spatial resolution, field-of-view and volume and material
recognition make the presented scanner and its geometry suitable for muon tomograph
Thermal and fast neutron dosimetry using artificial single crystal diamond detectors
In this work we propose the artificial Single Crystal Diamond (SCD) detector covered with a thin layer (0.5 μm/4 μm) of 6LiF as a simultaneous thermal and fast neutron fluence monitor. Some interesting properties of the diamond response versus the neutron energy are evidenced thanks to Monte Carlo simulation using the MCNPX code which allows to propose the diamond detector also as an ambient dose equivalent (H(10)) monitor (REM counter). © 2011 Elsevier Ltd. All rights reserved
Ageing test of the ATLAS RPCs at X5-GIF
An ageing test of three ATLAS production RPC stations is in course at X5-GIF,
the CERN irradiation facility. The chamber efficiencies are monitored using
cosmic rays triggered by a scintillator hodoscope. Higher statistics
measurements are made when the X5 muon beam is available. We report here the
measurements of the efficiency versus operating voltage at different source
intensities, up to a maximum counting rate of about 700Hz/cm^2. We describe the
performance of the chambers during the test up to an overall ageing of 4 ATLAS
equivalent years corresponding to an integrated charge of 0.12C/cm^2, including
a safety factor of 5.Comment: 4 pages. Presented at the VII Workshop on Resistive Plate Chambers
and Related Detectors; Clermont-Ferrand October 20th-22nd, 200
- …